Abstract

The Swift mission Burst Alert Telescope (BAT) Detector Array thermal control system includes two propylene loop heat pipes (LHPs), eight ammonia constant conductance heat pipes (CCHPs), a radiator that has AZ-Tek's AZW-LA-II low alpha white paint, and precision heater controllers that have adjustable set points in flight. The Power Converter Box (PCB) and Image Processor Electronics (IPE) boxes (a primary and a redundant) of the BAT have Z93P white paint radiators. Swift was successfully launched into orbit on November 20, 2004. The spacecraft (S/C) was placed into a safehold mode on August 10, 2007 after an anomaly on inertial reference unit (IRU) #3. It was returned to inertial pointing on August 16 and instrument power up followed. This paper presents a thermal assessment of the BAT instrument thermal control system (TCS) shut down and recovery as a result of the S/C safehold mode. The recovery required starting up the LHPs manually.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.