Abstract

Valuable haemodynamic data can be derived from a properly positioned Swan-Ganz catheter. Unfortunately, a significant number of these catheters will, for one reason or another, become malpositioned. Withdrawing a catheter from a permanently wedged position presents little difficulty. Repositioning may, however, necessitate its advancement, with the attendant risk of bacterial contamination. We have solved this problem by making a protective sleeve from readily available latex drain and tubing, which fits securely over the haemostatic valve of a No. 8F Cordis introducer. Iodine solution is injected into the sleeve to provide a sterile environment for the Swan-Ganz catheter, which can then be repositioned as required without the risk of bacterial contamination, as verified by bacteriological studies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.