Abstract

Seroma formation after laparoscopic or robotic inguinal hernia repair is a known complication, causing nuisance to the patient and embarrassment to the surgeon. A method of fixing the lax pseudosac of direct inguinal hernia to Cooper's ligament by suturing, to prevent post-operative seroma formation, is discussed in this study. Seventy-two pseudosac fixations were done in a 'figure of eight technique' using non-absorbable suture in 56 patients. These patients were followed up 2 weeks and 6 weeks post surgery. None developed a seroma. The primary obliteration of pseudosac by suturing with non-absorbable suture to Cooper's ligament is a cheap and reliable method for prevention of post-operative seroma. However, it is time-consuming and dependent on the suturing skill of the surgeon.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.