Abstract

BackgroundAnkle syndesmotic injuries can be surgically managed with syndesmosis screws (SS) or suture button (SB) fixation. We performed a meta-analysis of randomized controlled trials (RCTs) aiming to compare the clinical and complication profiles of both modalities. MethodsA multi-database search up to 4th of March 2018 was performed according to PRISMA guidelines. All RCTs comparing both techniques and published in English were included. ResultsFive RCTs with a total of 280 patients (140 SB, 140 SS) were included for analysis. SB had a statistically significant higher AOFAS score at 1 year (mean difference=5.46, 95% CI=0.40–10.51, p=0.03) and lower implant failure rate (OR=0.03, 95% CI=0.01–0.15, p<0.001). Infection and wound issues were marginally higher with SB (OR=1.4, 95% CI=0.4–4.85, p=0.60). No other parameters showed statistically significant difference. ConclusionsBoth constructs yielded similar clinical outcomes. The 1 year AOFAS score was higher in SB but clinical significance is unlikely. SB had significantly fewer implant failures.Level of evidence: Level I.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.