Abstract

BackgroundThis study aimed to report the long-term survival of fixed-bearing medial unicompartmental knee arthroplasty (UKA) with a mean of 14-year follow-up, and to determine possible risk factors of failure.MethodsWe retrospectively evaluated 337 fixed-bearing medial UKAs implanted between 2003 and 2014. Demographic and radiographic parameters were measured, including pre-operative and post-operative anatomical femorotibial angle (aFTA), posterior tibial slope (PTS), and anatomical medial proximal tibial angle (aMPTA). Multivariate logistic regression analysis was applied to figure out risk factors.ResultsThe mean follow-up time was 14.0 years. There were 32 failures categorized into implant loosening (n = 11), osteoarthritis progression (n = 7), insert wear (n = 7), infection (n = 4), and periprosthetic fracture (n = 3). Cumulative survival was 91.6% at 10 years and 90.0% at 15 years. No statistically significant parameters were found between the overall survival and failure groups. Age and hypertension were significant factors of implant loosening with odds ratio (OR) 0.909 (p = 0.02) and 0.179 (p = 0.04) respectively. In the insert wear group, post-operative aFTA and correction of PTS showed significance with OR 0.363 (p = 0.02) and 0.415 (p = 0.03) respectively. Post-operative aMPTA was a significant factor of periprosthetic fracture with OR 0.680 (p < 0.05).ConclusionsThe fixed-bearing medial UKA provides successful long-term survivorship. Tibial component loosening is the major cause of failure. Older age and hypertension were factors with decreased risk of implant loosening.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call