A survey was conducted to assess pressure management practices in water distribution systems. Most of the surveyed utilities agreed on the need to avoid low‐pressure episodes (< 20 psi). However, 56% of the utilities had no requirements for the maximum pressure delivered to customers, and 67% did not manage peak pressures in their systems. Only 13% of surveyed systems conducted pressure monitoring at critical locations—e.g., sites of highest or lowest pressure. Approximately 50% of systems reported at least one occurrence of negative pressure during the previous year; however, many more incidents of low and/or negative pressure may have gone undetected. The authors recommend that distribution system pressures be monitored in at least two locations in each pressure zone, representing the highest and lowest pressures. The recording interval could be set to 5–10 min with a 10‐s sampling interval. Impulse recording (when available) should be enabled to capture momentary pressure changes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.