Abstract

BackgroundVentilator-associated pneumonia (VAP) is a major cause of morbidity and mortality in patients receiving mechanical ventilation in India. Surveillance of VAP is essential to implement data-based preventive measures. Implementation of ventilator-associated events (VAE) criteria for surveillance has major constraints for low resource settings, which can lead to significant underreporting. Surveillance of VAP using common protocols in a large network of hospitals would give meaningful estimates of the burden of VAP in low resource settings. ObjectiveThis study leverages a previously established healthcare-associated infections (HAI) surveillance network to develop and test a modified VAP definition adjusted for Indian settings. MethodsIn this observational pilot study, thirteen hospitals from the existing HAI surveillance network were selected for developing and testing a modified VAP definition between February 2021 and April 2023. The criteria used for diagnosing VAP were adapted from the CDC’s Pediatric VAP definition and modified to cater to the needs of Indian hospitals. Designated nurses recorded each VAP event in a case report form (CRF) and also collected denominator data. The data was entered into an indigenously developed database for validation and analysis. At the time of data analysis, a questionnaire was sent to sites to get feedback on the performance of the modified VAP definitions. FindingsOut of 133,445 patient days and 40,533 ventilator days, 261 VAP events were recorded, with an overall VAP rate of 6.4 per 1,000 ventilator days and a device utilization ratio (DUR) of 0.3. A total of 344 organisms were reported from the VAP events. Of these, Acinetobacter spp (29.6%, 102) was the most frequent, followed by Klebsiella spp (26.7%, 92). Isolates of Acinetobacter spp (98%) and Enterobacterales (85.5%) showed very high resistance against Carbapenem. Colistin resistance was observed in 6% of Enterobacterales and 3.2% of Acinetobacter spp. InterpretationData from this pilot study needs to validated in the larger Indian HAI surveillance network so that it can help in wider implementation of this protocol in order to assess its applicability p VAP across India. . FundingThis work was supported by a grant received from the Indian Council of Medical Research (code I-1203).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.