Abstract

Although several surgical techniques for midclavicular fractures have been reported, Knowles pinning has rarely been compared with plating. The purpose of this study is to compare the clinical results of these two alternative techniques. There were 88 patients with midclavicular fractures surgically treated with either a Knowles pin or a plate. All patients were followed up for 12 months with a shoulder score evaluation. The Knowles pin group included 56 patients, with an average age of 40.1 years. The plate group included 32 patients, with an average age of 38.2 years. Both groups were similar in injury mechanism and fracture types (all p values>0.5). Plating has a significantly longer operation time, larger wound incision, higher pain level, more analgesic use, more complications and more symptomatic hardware (all p value<0.05). The shoulder score, union rate and healing time are not significantly different between the two groups (all p values>0.2). In conclusion, if the surgery of mid-third clavicular fractures is indicated, fixation with a Knowles pin has more advantages than plate fixation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.