Abstract

To evaluate post-operative complications and the recurrence rate after repair of large ventral incisional hernia with an open technique using intraperitoneal composite mesh and an associated aponeurotic overlay. This prospective study included a total of 280patients who underwent repair of large incisional hernia using Parietex(®) composite mesh. The post-operative mortality rate was 0.35%. Six patients (2%) developed subcutaneous surgical site infection without infection of the prosthesis. Six other patients (2%) developed a deep-seated infection; in three cases, the mesh had to be removed. Nine patients (3.2%) developed recurrent incisional hernia. Large ventral incisional hernias can be effectively treated by the intraperitoneal placement of Parietex(®) composite mesh overlaid by an aponeurotic graft; the incidence of complications in this prospective study was very low.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.