Abstract

The aim of the study is to compare the operative time and postoperative complication outcomes for bone-anchored hearing aid (BAHA) implants using two different techniques: the C-shaped incision technique and the linear incision technique. An analysis was carried out of 38 patients implanted with transcutaneous BAHAs during a 4-year period in a single otolaryngology department. The implantation was carried out under general anesthesia. Operative time was significant lower with the linear technique compared to the C-shaped technique (76.55min, SD 16.75 vs. 93.17min, SD 19.82; p = 0.007). There was no difference in postoperative complications between the two techniques. The use of linear incision for transcutaneous BAHA system implantation is associated with a reduced surgery time compared to the C-shaped technique, with no increase in postoperative complications.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.