Abstract

Background: Ascending aortic (AA) dilatation is common in patients with bicuspid aortic valve (BAV). In BAV replacement, surgery of the AA is indicated in the case if AA diameter exceeds 45 mm. Aortic valve replacement combined with an AA intervention is associated with increased risk of complications. The feasibility of the reduction ascending aortoplasty for correction of the dilated AA remains disputable.Aim: To analyze the results of BAV surgical replacement with simultaneous surgical correction of the borderline AA dilatation (45-50 mm) by the reduction aortoplasty (RAP) or supracoronary AA replacement (SPR).Materials and methods: This single center prospective non-randomized study included 53 patients with significant BAV stenosis and AA dilatation (45-50 mm), divided into 2 groups: BAV surgical replacement combined with RAP AA replacement (group 1, 36 patients) and BAV replacement with SPR (group 2, 17 patients). There were no significant differences between the patients of the two groups in their characteristics of the underlying disease, complications and comorbidities.Results: Hospital mortality was 0%. No between-group differences in the early postoperative course were found. At later term, 44 (81.5%) patients were assessed; median (dispersion) of the follow-up was 36 (25; 50) months. Two patients from the group 2 died during the follow-up. The long-term survival was better in the group 1 (p = 0.028). No differences in the combined adverse event rate were observed between the groups (p = 0.633). The median (dispersion) of the AA absolute increment and the rate of dilatation after RAP were 1.0 (0.0; 3.0) mm and 0.24 (0.00; 0.95) mm/year, respectively. The predictor of AA increment rate ≥ 2 mm/year was the baseline blood pressure level (odds ratio 1.321, 95% confidence interval 1.050-1.662; p=0.017). The threshold preoperative blood pressure value for the increased risk of the long-term AA expansion rate was 138 mmHg.Conclusion: The efficacy and safety of RAP and SRP combined with BAV replacement in AA borderline dilatation are similar. Combined BAV surgery and RAP is effective and safe in patients with systolic blood pressure level ≤ 135 mmHg. Combined BAV replacement with SRP seems reasonable in patients with arterial hypertension.

Highlights

  • dilatation is common in patients with bicuspid aortic valve

  • surgery of the Ascending aortic (AA) is indicated in the case if AA diameter exceeds

  • Aortic valve replacement combined with an AA intervention is associated with increased risk

Read more

Summary

Introduction

Ascending aortic (AA) dilatation is common in patients with bicuspid aortic valve (BAV). Дискутабельной остается применимость редукционной пластики ВА для коррекции расширения аорты при протезировании аортального клапана.

Objectives
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call