Abstract

IntroductionThe creation of a neophallus is a complex surgery that must meet functional and esthetic requirements. It is a long and demanding surgical process whose final stage consists of the implantation of a rigid or inflatable material that can be used to reproduce an erection. Data in the literature are scarce, with only the pioneering series present, which includes the use of the first devices and techniques. AimTo report the outcome of patients with phalloplasty after implantation of erectile implants using standardized surgical techniques and the use of recent prosthesis types with or without a vascular graft. MethodsThis is a retrospective hospital-based analysis of all patients with phalloplasty who underwent implantation of an erectile prosthesis from March 2007 to May 2015. Factors associated with complications were investigated by multivariate logistic regression analysis. Main Outcome MeasuresEarly-onset (during the first month after surgery) and late-onset complications, including erosion, infections, malpositioning, and dysfunction. ResultsSixty-nine patients were included in the study and 95 procedures were analyzed. After a median follow-up of 4 years (minimum = 169 days, maximum = 6.1 years), the original prosthesis was still in place in 43 patients (62.3%). Patients underwent phalloplasty after female-to-male transsexualism (n = 62, 89.9%), malformation (n = 4, 5.8%), or trauma (n = 3, 4.3%). The proportions for the different types of phalloplasty were 58% for forearm free flap phalloplasty (n = 40), 33.3% for suprapubic phalloplasty (n = 23), and 7% for other (n = 6). The erectile prostheses used were the two-piece AMS Ambicor (n = 71, 74.7%), the Ambicor with a vascular graft (n = 19, 20.0%), and the AMS 700CXR, AMS 700CX, or AMS600-650 (n = 5, 5.2%). There were no early-onset complications in 89 procedures (93.7%) and, when present, they were always related to infection (n = 4, 4.2%). Late-onset complications were erosion (n = 4, 4.2%), infection (n = 4, 4.2%), dysfunction (n = 10, 10.5%), and malpositioning (n = 12, 12.6%). No significant difference was observed for malpositioning (12.7% vs 10.5%, P = .87) and dysfunction (7.0% vs 10.5%, P = .78) between the AMS Ambicor prosthesis and the Ambicor prosthesis with a vascular graft. ConclusionThis study provides updated data on complications after the implantation of erectile implants. Multicenter studies, including the evaluation of patient satisfaction, are needed to increase our understanding of factors associated with the outcomes.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call