Abstract

To assess rates of surgical revision of glaucoma drainage devices (GDDs) from hypotony owing to overfiltration and its management. Retrospective case series. Demographic characteristics, type of GDD implanted, type of surgical revision, and outcomes were obtained from the charts of patients undergoing GDD implantation and > or = 1 subsequent GDD revision in 2002 to 2006. All surgical revisions performed owing to hypotony from overfiltration in the absence of a wound leak were identified. Of 1292 eyes undergoing GDD implantation, 21 (1.6%) developed hypotony owing to overfiltration requiring surgical revision: 15 eyes of 488 (3.1%) with a Baerveldt implant and 6 of 804 (0.7%) with an Ahmed (P=0.002). When including primary and secondary revisions, 6 of 12 eyes (50%) treated by using polyglactin suture ligation were successful (did not require additional surgery) compared with 8 of 10 (80%) undergoing suture ligation using prolene. Hypotony owing to overfiltration is an uncommon GDD-surgery complication. Understanding how to manage patients who develop this complication can improve patient outcomes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.