Abstract

Objectives Full median sternotomy (FMS) is the common surgical access for patients undergoing replacement of the ascending aorta (AA) with or without aortic valve replacement (AVR). The right anterior mini-thoracotomy (RAMT) approach has been increasingly adopted for AVR. This approach has been shown to decrease blood loss and hospital length of stay (LOS) compared with FMS. The RAMT approach may also be beneficial in selected patients requiring AA procedures with or without AVR. We present our initial clinical experience of patients who have undergone a RAMT for supracommissural replacement of the tubular AA with or without AVR. Methods This is a single-center retrospective review of 10 patients who underwent an elective RAMT for replacement of the tubular AA with or without AVR between November 2019 and January 2022. Clinical outcomes evaluated include 30-day mortality, intensive care and hospital LOS, time to extubation, operative times, as well as postoperative complications such as stroke and bleeding. Results Median cross-clamp and cardiopulmonary bypass times were 109 and 148 min, respectively. Median time to extubation was 2.5 h and median intensive care unit and hospital stay were 2 and 10 days, respectively. There were two re-thoracotomies for postoperative bleeding and two cases of sub-xiphoidal pericardial drainage for pericardial effusion. There were no strokes and no in-hospital nor 30-day mortalities. Conclusions The replacement of the AA with or without concomitant AVR can be performed through a RAMT in carefully selected patients. However, the safety of this approach, as compared to full/partial median sternotomy, remains to be proven.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call