Abstract

Numerical and experimental investigations were conducted in a transonic centrifugal compressor stage composed of a backswept splittered unshrouded impeller and a vaned diffuser. Unsteady 3D simulations were performed with the code elsA that solves the turbulent averaged Navier-Stokes equations, at three operating points: choked flow, peak efficiency and near surge. Unsteady pressure measurements up to 150 kHz were carried out in the entry zone of the vaned diffuser (in the vaneless space and in the semi-vaneless space) when the compressor came into surge. These static pressure sensors were mounted on the shroud enwall. The paper focuses on the vaneless and semi-vaneless space where the surge originates. A detailed analysis of the flow pattern coming from the unsteady computations from choked flow towards surge led to identify the physical mechanisms involved in the surge inception. It is shown that, when approaching surge, the flow is destabilized by a severe modification of the shock system in the vaned diffuser inlet. The first perturbation is acquired from the transducer located just upstream of the shock foot (i.e. on the vane suction side surface), indicating a movement of the shock towards the vaneless space. This perturbation travels upstream and leads to the strongest short-wavelength perturbation acquired from the transducer located just upstream of the vane leading edge. This strongest short-wavelength perturbation which level may reach almost four times the mean exit pressure value triggers the full scale instability.