Abstract

A pressure system is described for measuring the pressure dependence of surface tension using digital image processing techniques on pendant drops in systems where the miscibility changes with both temperature and pressure. Measurements can be performed at pressures up to 40 MPa and temperatures up to 423 K. This high-pressure rig allows, additionally, the simultaneous measurement of both phase density and composition. The system is tested with the methane-pentane system at 313.15 K and pressures up to 15.6 MPa; the results compare well with literature data and with values calculated using the Peng-Robinson equation of state in conjunction with the gradient theory approach to computing surface tension, thus validating the experimental technique. Density profiles of the components through the interfacial layer have also been calculated using gradient theory. The Wegner extended scaling approach has been applied to all of the data sets to estimate the critical pressure for this system, which is found to be 16 MPa at 313.15 K.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.