Abstract

Precise three-dimensional measurements of surfaces are significant in many fields. Usually, three-dimensional descriptions of the object surface have to be acquired by contact measure probe or other non-contact equipment. The paper proposed a novel surface reconstruction method that uses camera relative irradiance via the image gray-scale value information under fixed ring light. After calibrations of the measurement condition, just one image of the object is necessary to reconstruct the surface. The method mainly involves two aspects: the calibration process and the surface reconstruction process. The purpose of the calibration process is to find the relation between the image gray-scale value and the relative irradiance of the charge-coupled device sensor in different expose conditions. The surface reconstruction mainly focuses on the relation between the irradiance and height information. The experiment result shows the relative error of the illumination measurement result obtained using charge-coupled device camera is less than 2.91%. Reconstruction error is mainly result from the truncation error of algorithm calculation. An example is presented to verify the performance of this technique. The reconstruction experiments demonstrated that it can successfully measure the geometrical characteristics from the specified view of the object.

Highlights

  • As a summary of product, quality is used to determining the product capability to meet the needs, fulfill functions, and have a utility effect.[1]

  • We developed a camera system connected to a personal computer (PC) for the surface reconstruction

  • As addressed above, using camera relative irradiance via the image gray-scale value information under fixed ring light, a surface reconstruction method is proposed in this article

Read more

Summary

Introduction

As a summary (measurable quantities and characteristics) of product, quality is used to determining the product capability to meet the needs, fulfill functions, and have a utility effect.[1]. After brief introduction of luminance and theoretic deduction, the relation between the image gray-scale value and the relative irradiance of the CCD sensor is obtained (section ‘‘Introduction’’). The purpose of calibration process is to find the relation between the image gray-scale value and the relative irradiance of the CCD sensor.

Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.