Abstract

Phase-locked PSP and PIV measurements were used to study the evolution of three-dimensional disturbances produced by an oscillating fence actuator immersed in a zero pressure gradient turbulent boundary layer. For the single fence frequency studied, strong three-dimensionality is observed in the vortical structure that varies along the span of the fence soon after the fence enters the flow. At the midspan, the structure grows, weakens, and convects faster than at other locations. As the fence height increases, the data indicate that the vortical structure terminates near the edge of the fence. In contrast, the vortex structure terminates on the plate surface adjacent to the fence edge as the fence descends, similar to a wake vortex of a stationary obstacle. This study demonstrates that the combined use of surface and flow-field diagnostics provide a link between flow field and surface features, yielding an understanding of the flow that would have not been possible with any one technique.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.