Abstract

In this study the degradation and reliability of a plastic encapsulated RF switching device were assessed by comparing several lots of a device that came directly off the assembly line to several other lots which had been subjected to accelerated stress testing. Comparisons of the structure, die and wirebonds were based on the results of examinations using optical microscopy, X-ray analysis, scanning acoustic microscopy, environmental scanning electron microscopy and wire bond pull tests.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.