Abstract

Surface charge accumulation on insulator surface can have great influence on surface flashover performance. An experimental system is established to investigate surface charge accumulation and decay characteristics of Al2O3-filled epoxy resin insulators in 0.1 MPa SF6 under DC voltages. Surface potential is recorded by a Kelvin vibrating probe connected to an electrostatic voltmeter. By pre-depositing charges on insulator surface, the influence of surface charges on surface flashover performance is studied. The results reveal that surface charge distribution appearance is the combined effect of electrode injection, back discharge and gas ionization. Surface charge distribution has obvious polarity effect. It is concentrated near the HV electrode under positive voltages and dispersed under negative voltages. The difference in positive and negative surface flashover voltage is attributed to the difference in surface charge distribution under DC voltages of different polarities. Surface charge decay contains two stages, which satisfies the law of double exponential function. At first stage, surface charge decays fast, which corresponds to charges escaping from shallower traps. While it decays slowly at the second stage, which corresponds to charge escaping from deeper traps. Surface charge decay process is dominated by surface conductivity mechanism. The pre-deposited charges on insulation surface have great influence on surface flashover performance. The deposited positive charges can increase positive flashover voltage but decrease negative flashover voltage.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call