Excellent life performance is being achieved for ac plasma display panels through understanding of the causes of voltage changes, surface overcoat material research, and adjustment of the manufacturing process to eliminate contaminants. It has been found that surface aging phenomena are dominant in many practical cases. Because of prefereutial operation patterns (i.e., alpha numerics), a differential aging pattern may evolve. The differential pattern is the result of voltage changes which are different for heavily operated and lightly or nonoperated cells. It is shown that the nature and extent of surface changes are dependent on overcoat material selection and the presence (or absence) of contaminants introduced during manufacture. With the use of thin overcoat layers in contact with the gas, it is necessary to be aware of the possibility of surface film removal by sputtering. The effects of significant variables: gas pressure and composition surface material, and operating voltage are discussed.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.