Abstract

Laparoscopic and endoscopic ultrasound is used to assess resectability of gastrointestinal malignancies. Lymph node size greater than 1 cm is a criterion used to identify suspicious nodes. We define size and echo characteristics of suprapancreatic and periportal nodes to determine if this criterion is reliable for suprapancreatic and periportal lymph nodes. A prospective study of 21 patients with nonacute gallbladder disease was performed. Each underwent laparoscopic cholecystectomy with intraoperative ultrasound. The suprapancreatic and periportal nodes were evaluated in a transverse and longitudinal axis. Length and width measurements were taken in both orientations. Length-to-width ratios were calculated. Shape and echo textures were characterized. The mean size of both nodes was greater than 1 cm in the transverse and longitudinal orientation. Two nodes were "round." Remaining nodes were "oblong." All nodes had a hyperechoic center with a hypoechoic rim. In suprapancreatic and periportal lymph nodes, size greater than 1 cm should not be used as criterion for malignancy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.