Abstract

The influence of probe correction in spherical near-field measurements on signals from outside the test volume is investigated theoretically and experimentally. It is found that the suppression of reflections obtained by a directive probe is not disturbed by the probe correction. A geometric relation between the antenna "minimum sphere" and the probe pattern beamwidth is established, whose satisfaction guarantees the absence of numerical instabilities in the far-field computation. The condition is sufficient, but not necessary if the "minimum sphere" of the antenna is in the near field of the probe.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.