Abstract

BackgroundPublic access defibrillators (PADs) are now available for more efficient and rapid treatment of out-of-hospital sudden cardiac arrest. PADs are used normally by untrained people on the streets and in sports centers, airports, and other public areas. Therefore, automated detection of ventricular fibrillation, or its exclusion, is of high importance. A special case exists at railway stations, where electric power-line frequency interference is significant. Many countries, especially in Europe, use 16.7 Hz AC power, which introduces high level frequency-varying interference that may compromise fibrillation detection.MethodMoving signal averaging is often used for 50/60 Hz interference suppression if its effect on the ECG spectrum has little importance (no morphological analysis is performed). This approach may be also applied to the railway situation, if the interference frequency is continuously detected so as to synchronize the analog-to-digital conversion (ADC) for introducing variable inter-sample intervals. A better solution consists of rated ADC, software frequency measuring, internal irregular re-sampling according to the interference frequency, and a moving average over a constant sample number, followed by regular back re-sampling.ResultsThe proposed method leads to a total railway interference cancellation, together with suppression of inherent noise, while the peak amplitudes of some sharp complexes are reduced. This reduction has negligible effect on accurate fibrillation detection.ConclusionThe method is developed in the MATLAB environment and represents a useful tool for real time railway interference suppression.

Highlights

  • Public access defibrillators (PADs) are available for more efficient and rapid treatment of out-of-hospital sudden cardiac arrest

  • A better solution consists of rated analog-to-digital conversion (ADC), software frequency measuring, internal irregular re-sampling according to the interference frequency, and a moving average over a constant sample number, followed by regular back re-sampling

  • The method is developed in the MATLAB environment and represents a useful tool for real time railway interference suppression

Read more

Summary

Introduction

Public access defibrillators (PADs) are available for more efficient and rapid treatment of out-of-hospital sudden cardiac arrest. A special case exists at railway stations, where electric power-line frequency interference is significant. Especially in Europe, use 16.7 Hz AC power, which introduces high level frequency-varying interference that may compromise fibrillation detection. Public access defibrillators (PADs) are available for more rapid and efficient treatment of out-of-hospital sudden cardiac arrest [1,2]. They are strongly recommended in The American Heart Association and the International Liaison Committee on Resuscitation Guidelines [3]. The interference induced may compromise the fibrillation detection [8,9]

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.