Abstract

The Suppression Head Impulse (SHIMP) test was introduced as an alternative to the Head Impulse Paradigm (HIMP) to overcome challenges in VOR gain calculation due to the interference of covert saccades. The objectives of this study were (1) to determine if SHIMP, compared to HIMP, reduces covert saccades in BV patients and (2) to define the agreement on diagnosing BV between SHIMP and HIMP. First, the number of covert saccades was compared between SHIMP and HIMP. Secondly, VOR gain was compared between SHIMP and HIMP. Lastly, the agreement between SHIMP and HIMP on identifying BV (horizontal VOR gain <0.6) was evaluated. A total of 98 BV patients were included. To our knowledge, this is the largest study population on SHIMP testing in BV patients. Covert saccades were significantly reduced, and a lower VOR gain was found during SHIMP compared to HIMP (p < 0.001). However, the clinical relevance of these statistically significant differences is small. In 93% of the patients, an agreement was found between the two paradigms regarding the diagnosis of BV, and both paradigms detect BV in the vast majority of patients.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.