Abstract

A suppressed ion chromatography (IC) technique has been evaluated as a chemical monitoring tool for detecting major anions (F −, Cl −, NO 3 − and SO 4 2−) of condensed steam in geothermal power plants. It is shown that the suppressed IC technique provides a suitable means for preventing possible damage to generating equipment in the geothermal industry. An electrical conductivity detector (0.1 μS sensitivity) with an anion-exchange column (IonPac AS4A-SC), a micro-membrane suppressor (AMMS II), and an isocratic high-pressure pump system were successfully used for detecting low concentrations of inorganic anions. Method detection limits for the anions of interest were <0.184 mg/L. Details of the IC methodology as well as some experimental results obtained during its application for the chemical monitoring of geothermal steam pipes are also described.