Abstract
In this work, a novel methodology based on the combination of MIP technology with micro solid-phase extraction in a hollow fibre device for the trace enrichment and cleanup of triazines in environmental waters is described. All parameters affecting both migration of triazines from samples to the lumen of the fibre and rebinding into MIP sites have been carefully optimized. Final conditions included, addition of 20% NaCl to the sample to produce salting-out effect, extraction of analytes during 45min with orbital stirring at 750rpm, and then washing the fibre with toluene during 5min to allow selective recognition of triazines before elution in HPLC inserts containing 450μL of a methanol/acetic acid mixture (95/5, v/v). Under optimum conditions, quantitative recoveries for simazine, cyanazine, atrazine, propazine and terbutylazine, were achieved both in surface, ground and tap water samples, with relative standard deviations lower than 10.6%, and limits of detection in the low ngL−1 concentration level.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.