Abstract

This paper is the first of a two-part series investigating the mechanical behavior of rammed aggregate pier (RAP) groups supporting isolated rigid footings. The first paper presents the experimental test results from instrumented load tests performed on two different 2.3 m square reinforced concrete footings supported by four 0.76 m diameter RAPs of two different pier lengths—2.8 and 5.1 m . Comparisons are made to load tests performed on three isolated RAPs of the same diameter and lengths. Instrumentation consisted of total stress cells, inclinometers, and tell-tale reference plates. Soil conditions at the test site were evaluated using various in situ testing techniques and consist of relatively uniform soft alluvial clay overlain by a 1-m-thick desiccated layer. Interpretations of the test results focused on load-deformation behaviors of the isolated piers and pier groups, group efficiencies in terms of settlement and bearing capacity, stress concentrations as a function of applied load at the top of ...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.