Abstract

A long calibration procedure limits the use in practice for a motor imagery (MI)-based brain-computer interface (BCI) system. To tackle this problem, we consider supervised and semisupervised transfer learning. However, it is a challenge for them to cope with high intersession/subject variability in the MI electroencephalographic (EEG) signals. Based on the framework of unsupervised manifold embedded knowledge transfer (MEKT), we propose a supervised MEKT algorithm (sMEKT) and a semisupervised MEKT algorithm (ssMEKT), respectively. sMEKT only has limited labelled samples from a target subject and abundant labelled samples from multiple source subjects. Compared to sMEKT, ssMEKT adds comparably more unlabelled samples from the target subject. After performing Riemannian alignment (RA) and tangent space mapping (TSM), both sMEKT and ssMEKT execute domain adaptation to shorten the differences among subjects. During domain adaptation, to make use of the available samples, two algorithms preserve the source domain discriminability, and ssMEKT preserves the geometric structure embedded in the labelled and unlabelled target domains. Moreover, to obtain a subject-specific classifier, sMEKT minimizes the joint probability distribution shift between the labelled target and source domains, whereas ssMEKT performs the joint probability distribution shift minimization between the unlabelled target domain and all labelled domains. Experimental results on two publicly available MI datasets demonstrate that our algorithms outperform the six competing algorithms, where the sizes of labelled and unlabelled target domains are variable. Especially for the target subjects with 10 labelled samples and 270/190 unlabelled samples, ssMEKT shows 5.27% and 2.69% increase in average accuracy on the two abovementioned datasets compared to the previous best semisupervised transfer learning algorithm (RA-regularized common spatial patterns-weighted adaptation regularization, RA-RCSP-wAR), respectively. Therefore, our algorithms can effectively reduce the need of labelled samples for the target subject, which is of importance for the MI-based BCI application.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.