Abstract

Non-biodegradable superparamagnetic particles, in plain and viscous aqueous suspensions, were used as an oral contrast medium in 34 patients with known or suspected malignant lymphoma. The contrast effect, the occurrence of artifacts, and the distribution were evaluated in the plain and the viscous aqueous suspensions, and the diagnostic information received from abdominal MR examinations performed without bowel contrast medium was compared with that of post-contrast examinations. Magnetic particles in the concentration of 0.5 g/l displayed a good contrast effect at 0.5 T, and helped in differentiating the intestine from adjacent tissues, resulting in increased diagnostic information in abdominal MR imaging. In the patients given the viscous aqueous suspension the occurrence of artifacts caused by the magnetic particles decreased considerably, and the distribution was homogeneous and improved compared with that in patients given the plain aqueous suspension.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.