Abstract
Modulation of ventricular parasystole by sinus beats has been shown both in vitro and in vivo to result in a classic biphasic phase-response curve. The first clinical presentation of 3 cases of supernormal modulation of ventricular parasystole resulting in a triphasic phase response curve is reported. Supernormal modulation reflects an unexpected early enhancement expedition of the ectopic ventricular impulses. An alternative explanation for the triphasic phase-response curve is the discharge and resetting of the parasystolic focus by critically timed sinus impulses.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.