A 29-year-old woman with an implanted AAI mode permanent pacemaker, who had undergone catheter ablation for inappropriate sinus tachycardia 4 times, experienced complications of superior vena cava (SVC) syndrome. Severe stenosis of the SVC wall was observed in computed tomograms. During balloon dilation for the treatment of SVC syndrome, the SVC was ruptured, resulting in cardiac tamponade. An emergency operation was performed using percutaneous cardiopulmonary support (PCPS). A longitudinal tear 1 cm in length was identified at the junction of the right atrium and the SVC, requiring a patch plasty using an autologous pericardium 2.5 cm x 3 cm in size. SVC rupture is a complication to be completely avoided when we perform balloon dilation for the treatment of SVC syndrome. Therefore, the indication of balloon dilation for the treatment of SVC syndrome requires critical examination and attention.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.