Abstract

BackgroundUntil now there have been no prospective studies describing the results of using the superior clavicle plate with lateral extension in patients with displaced lateral clavicle fractures (Neer type 2). The purpose of this study was to evaluate the results of applying this plate for this specific type of fracture.Materials and methodsIn this prospective study, seven patients (mean age 43, M:F; 6:1) with a fresh displaced lateral clavicle fracture were evaluated with a mean follow-up of 10 months. Analysis included functional and subjective outcome, time until union, time until return to work, and complications.ResultsAll patients achieved clinical and radiological union within 6–12 weeks. Full range of motion as well as a return to work was achieved in most cases within 2 weeks. The mean Constant score was 98 (range 90–100), the DASH score was 3.6 (range 0–11.4), and the Shoulder Rating Questionnaire score was 97 (range 96–100). No major complications were encountered. Three patients required plate removal: two because of a prominent and subcutaneous plate and one because of an intra-articular screw.ConclusionsIn this study, use of the superior clavicle plate with lateral extension yielded excellent results in the treatment of this difficult fracture. In particular, patients acquired full range of motion within 2 weeks, reflecting the stability of the osteosynthesis achieved with this implant.

Highlights

  • The treatment of displaced lateral clavicle fractures is controversial

  • Background Until now there have been no prospective studies describing the results of using the superior clavicle plate with lateral extension in patients with displaced lateral clavicle fractures (Neer type 2)

  • The purpose of this study was to evaluate the results of applying this plate for this specific type of fracture

Read more

Summary

Introduction

Conservative treatment may lead to good functional results in a selected group of patients. Since Neer [3, 4] first described fixing these fractures with two transarticular K-wires, many techniques and methods have been described for fixation. This indirectly suggests that these methods do not always yield the desired results [5]. Until now there have been no prospective studies describing the results of using the superior clavicle plate with lateral extension in patients with displaced lateral clavicle fractures (Neer type 2). Materials and methods In this prospective study, seven patients (mean age 43, M:F; 6:1) with a fresh displaced lateral clavicle fracture were evaluated with a mean followup of 10 months. Analysis included functional and subjective outcome, time until union, time until return to work, and complications

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call