Abstract

We report the first successful extraction of accumulated ultracold neutrons (UCN) from a converter of superfluid helium, in which they were produced by downscattering neutrons of a cold beam from the Munich research reactor. Windowless UCN extraction is performed in vertical direction through a mechanical cold valve. This prototype of a versatile UCN source is comprised of a novel cryostat designed to keep the source portable and to allow for rapid cooldown. We measured time constants for UCN storage and extraction into a detector at room temperature, with the converter held at various temperatures between 0.7 and 1.3 K. The UCN production rate inferred from the count rate of extracted UCN is close to the theoretical expectation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.