Abstract

<p>This study investigated optimum operating conditions of supercritical water oxidation (SCWO) for octol and compared the degradation of its components TNT (2,4,6-trinitrotoluene) and HMX (octahydro-1,3,5,7- tetranitro-1,3,5,7-tetrazocine, octogen) under the same conditions. Pilot scale experiments were conducted at various temperatures, reaction times and oxidant amounts. Removal efficiency, by-product analysis and toxicity tests were selected as the performance criteria for the SCWO. Optimum conditions were determined as a temperature of 500 C, 120 s of oxidation time and an oxidant ratio of 150%. Removal of octol was achieved at a rate of 99.99%, while TNT and HMX were removed individually at a rate of ~85% when they existed in the wastewater. No toxicity was observed at the end of the octol oxidation, whereas toxicity was found in the TNT and HMX oxidation due to the formation of TNT isomer and aniline. Higher initial organic material concentrations promoted the removal rates. These results demonstrated that SCWO can be effectively used for the degradation of ammunition wastewater even when concentrations are high.</p>

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.