Abstract

The aim of the present study was to develop an optimization procedure for supercritical fluid extraction parameters, in order to obtain the highest possible yield of sugars and cyclitols from plant material. Response surface methodology based on Box-Behnken design was applied to evaluate the effect of: temperature (40, 60, 80°C), pressure (100, 200, 300bar), and co-solvent (methanol) percentage (20, 25, 30%). As a result of the optimization process, we found that the highest amount of sugars (15.02 mg/gof dried material) and cyclitols (0.86 mg/g of dried material) was obtained when the following parameters were applied: 80°C, 228 bar, and 30% of methanol. Moreover, co-solvent concentration and temperature had a higher influence onto the obtained amounts compared with the pressure.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.