Abstract

Needs for neutron detection and monitoring in high neutron flux environments are increasing in several different fields. A completely solid-state, current mode bolometric detector is constructed as a solid substrate transition edge sensor based on a high-Tc\\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{mathrsfs} \\usepackage{upgreek} \\setlength{\\oddsidemargin}{-69pt} \\begin{document}$$_c$$\\end{document} superconducting meander. The detector consists of four individual pixels of which three pixels include 10B4C\\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{mathrsfs} \\usepackage{upgreek} \\setlength{\\oddsidemargin}{-69pt} \\begin{document}$${^{10}{\\hbox {B}}_{4}\\hbox {C}}$$\\end{document} neutron absorption layers. The absorbed energy per neutron absorption reaction is modelled and compared to experimental data. The response of the tested detector is directly correlated to a cold neutron beam with a flux of 1.8×108n/cm2/s\\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{mathrsfs} \\usepackage{upgreek} \\setlength{\\oddsidemargin}{-69pt} \\begin{document}$${1.8\ imes 10^{8}}\\,{\\hbox {n}/{\\hbox {cm}}^2/\\hbox {s}}$$\\end{document} modulated by a slit. The signal is found to be an order of magnitude higher than the thermal background. The dynamics described by the temporal saturation constants is governed by a modulation frequency less than 1Hz\\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{mathrsfs} \\usepackage{upgreek} \\setlength{\\oddsidemargin}{-69pt} \\begin{document}$${1}\\hbox { Hz}$$\\end{document}. The thermal response is dynamic and never fully saturates for 50s\\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{mathrsfs} \\usepackage{upgreek} \\setlength{\\oddsidemargin}{-69pt} \\begin{document}$${50}\\hbox { s}$$\\end{document} exposures. The efficiency for this proof-of-principle design is 1–2%. Possibilities for optimization are identified, that will increase the efficiency to become comparable to existing solid boron-10 detectors. The existing detectors with event-based read-out have limited functionality in high flux environments. The superconducting bolometer described in this work using current-mode readout will pave the way for high flux applications.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call