Abstract

This paper analyzes the in-flight performance of the Suomi National Polar-orbiting Partnership Ozone Mapping & Profiling Suite (OMPS) nadir instruments and evaluates sensors’ on-orbit calibrations after sensors’ two-year operation. All uncertainty values quoted in this paper are 1−σ values unless stated otherwise. With the data collected from in-flight nominal calibration, our results have demonstrated that sensor performance complies with the system specifications in most cases. The largest term in the wavelength-dependent albedo calibration uncertainty for Nadir Mapper is the cross-track position difference effect of 2.5%. Final adjustments of stray light and wavelength variation are still being made to optimize OMPS sensor data records before reaching the validation mature level.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.