Abstract

Sulfide Stress Cracking (SSC) of API-X100 high strength low alloy steel was evaluated in NACE solution “A” at room temperature. The corrosion rate, utilizing electrochemical polarization techniques, in the solution was 97 mpy. Proof ring testing, per NACE TM-0177, generated an SSC threshold stress value of 46% of yield strength. SSC susceptibility was caused by the high corrosion rate which formed corrosion pits that acted as crack initiation sites on the metal surface and provided more hydrogen to migrate into the steel. In addition, the X100 inhomogeneous microstructure provided a high density of hydrogen traps which promoted hydrogen embrittlement.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.