Hearing loss greater than 30 dB over three contiguous pure-tone frequencies occurring within a three day period is defined as sudden hearing loss. It is usually sensorineural (SSNHL), unilateral and appears as an otologic emergency. SSNHL has many possibile etiologies such as: labyrinthine viral infection, ischemic or hemorrhagic illness, trauma, immuno-mediated inner ear disease, tumor, inner ear malformation, and an imbalance between perilymphatic and endolymphatic fluid pressure. Nevertheless in almost 80% of cases SSNHL belongs to the idiopathic category because the etiology is unknown. The aim of this study was to test the diagnostic impact of two MR devices. Fifteen cases of SSNHL studied with a 1.5 T unit in our hospital between January 2006 and December 2008 within two weeks of the onset were retrospectively evaluated. Since January 2009 three more patients affected by SSNHL have been scanned with a 3T MR unit. We discuss the diagnostic sensitivity, clinical usefulness and the cost-benefit ratio of the MR systems.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.