Abstract

TECHNIQUE a sterilised drain set is used; small side holes are made in the tubes using scissors (average 6–10 holes) (Fig 1). The drip bag is emptied and a negative pressure is created (Fig 2). (Saline is used for the operation and is not discarded.) The drip set is connected to the bag to act as a suction drain. The roller clamp can be used to control flow and prevent the loss of negative pressure when changing the bottle. it can also be used as a simple drain. The closed drainage system helps to prevent infection. DISCUSSION We have used this technique in over 50 patients in Gadarif Teaching hospital. it is effective, cheap, removal is simple and we did not encounter any problems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.