Abstract

A technique utilizing suction decompression of large aneurysms to allow safer application of a clip is described. Large aneurysms are punctured with a No. 21 scalp vein needle attached to the operating room suction device. This procedure causes relaxation of the aneurysm itself and allows safer application of the clip. The technique has been used in six cases of giant aneurysms.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.