Abstract

Cardiogenic shock resulting from transplant rejection is a serious complication with high mortality and morbidity. Often resistant to maximal medical therapy, this condition frequently requires mechanical circulatory support until recovery or retransplantation. We present a 52-year-old patient with multiorgan failure secondary to acute graft rejection after orthotopic heart transplantation. Maximal medical therapy was not successful, and the patient was bridged to recovery with an Impella LP 5.0 (Abiomed Inc, Danvers, MA) left ventricular assist device (LVAD). The relative merits of this therapeutic approach are outlined and discussed. The patient was discharged 3 weeks after LVAD removal and remains clinically stable.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.