Abstract
A 7-year-old child underwent surgical excision of a benign mesothelioma of the pleura near the right lower lung. Although insertion of a wire-reinforced endotracheal tube through the left main bronchus was attempted for one-lung ventilation to secure the surgical field of view, the attempt failed. Therefore, an endotracheal tube was inserted into the trachea, and an Arndt endobronchial blocker (Cook Medical, Bloomington, IN, USA) was placed in the right intermediate bronchus under bronchoscopic guidance to selectively block the right lower and middle lobes. The surgery was performed while ventilating the right upper lobe and left lung, and no specific intraoperative adverse events occurred.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.