Abstract

A 45-year-old man, who was implanted with an inferior vena cava (IVC) filter in his infrarenal IVC, had a complication of deep vein thrombosis (DVT) propagation from the IVC, beyond the IVC filter, to the right calf and left external iliac veins. The entire IVC filter was covered with a massive thrombus. We first decided to retrieve the IVC filter itself, which was suspected of causing metallic allergy. The thrombotic IVC filter was successfully retrieved using multi-step catheter intervention. To our knowledge, this is the first case report to describe successful multi-step catheter intervention for retrieval of an IVC filter covered with a massive thrombus.<Learning objectives: Inferior vena cava (IVC) filter thrombosis is one of the most serious IVC filter complications. It is difficult to retrieve the IVC filter covered with a massive thrombus. Multi-step catheter intervention technique may be useful to retrieve an IVC filter with thrombotic occlusion.>

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.