Abstract

Embolic stroke is a common complication in patients on ventricular assist devices in both adults and children. The reported incidence of strokes in children supported by VAD's varies from 7 to 38%. The rapid increase in recent years in the availability of both adult and pediatric VADs will likely add to the overall prevalence of strokes in patients being bridged to heart transplant. Strokes in this population can be lethal as they frequently necessitate withdrawal of the extracorporeal device support and withdrawal from the organ transplant waiting list. We present a case of a fully anti-coagulated 29-month-old supported on a Berlin EXCOR LVAD (Berlin, Germany) with embolic stroke which was treated successfully with direct thrombolysis with recombinant tissue plasminogen activator. This is the first report which uses intra-arterial thrombolytics while on a ventricular assist device in a pediatric patient.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call