Abstract

ObjectivesAirway management during anaesthesia in cats is always a demanding task and is associated with several complications. The aim of this study was to evaluate the practicability and complications during feline-specific laryngeal mask placement in anaesthetised cats as an alternative to endotracheal intubation.MethodsIn this prospective clinical study, laryngeal masks were placed in 148 anaesthetised cats. Success of placement was evaluated by capnography.ResultsPlacement was possible at the first attempt in 136 cats, at the second attempt in eight cats and at the third attempt in one cat. In one cat, placement was not possible. Two cats were excluded. Failure to position the laryngeal mask at the first attempt was not different between laryngeal mask sizes (P = 0.313) or positioning during placement (P = 0.406). In nine cats, the laryngeal mask dislocated during the procedure. Dislocation occurred more often in the dorsal position than in the sternal (P = 0.018) and right lateral positions (P = 0.046). Mucous obstruction of the laryngeal mask occurred in one of these cats and regurgitation in another. Material-related issues, such as disconnection of the parts of the laryngeal mask and leakage of the balloon, were observed in 2/8 laryngeal masks.Conclusions and relevanceThe placement of a feline-specific laryngeal mask was easy to perform. In about 7% of the cases, replacement of the device was required due to mispositioning or dislocation. Full monitoring, including capnography, should be provided to uncover dislocation and airway obstruction immediately.