Abstract

IntroductionIntramedullary (IM) nails are considered the ‘gold’ standard treatment for subtrochanteric femoral fractures. The incidence and risk factors for re-operation in subtrochanteric fractures remain unclear. Furthermore, no studies have compared the outcomes of different nailing systems used to treat subtrochanteric fractures in the same study population.Aims/objectivesOur study aimed to (i) investigate the cumulative incidence and factors associated with an increased risk of re-operation in subtrochanteric fractures treated with a long intramedullary (IM) nail, (ii) compare the outcomes of subtrochanteric fractures treated with long Affixus and Gamma nails, and (iii) establish whether the addition of a proximal anti-rotation screw in the Affixus nail confers any clinical benefit.MethodsA retrospective review of all adult patients admitted to a level 1 trauma centre with a subtrochanteric femur fracture treated with a long cephalomedullary IM nail over an 8-year period was conducted. Exclusion criteria were primary surgery performed at another institution, prophylactic nailing because of tumours, incomplete fractures, and patients who were lost to follow-up or died before fracture healing. Data variables were assessed for normality prior to determining the use of either parametric or non-parametric tests. Logistic regression analysis was performed to identify potential factors associated with re-operation. For the comparison between the two nail types, patients were matched into two groups of 119 each by age (10-year intervals), gender and mechanism of injury (low energy, high energy and pathological fractures). A p-value < 0.05 was considered significant. The Kaplan–Meier nail survival curve was used to demonstrate the survival of each nail. Data were analysed using the statistical package R (R version 3.6.0).ResultsA total of 309 subtrochanteric fractures were treated with a distally locked long IM nail (re-operation rate: 22.33%) over an 8-year period. Logistic regression identified six factors associated with an increased risk of re-operation, including age < 75 years old, use of a long Gamma nail, pre-injury coxa-vara femoral neck shaft angles, an immediate post-operative reduction angle of > 10° varus, deep wound infection and non-union.Following matching, we compared the two long cephalomedullary nailing systems used (Gamma versus Affixus nail). The only differences identified from the unadjusted analysis were a higher overall incidence of nail failure in Gamma nails due to any cause, re-operation, and impingement of the nail tip distally against the anterior femoral cortex. When we corrected for covariates, no significant differences remained evident between the two nails. From the Kaplan–Meier nail survival curves, however, the Affixus nail demonstrated better survivorship up to 5 years post-implantation in terms of nail failure and re-operation for all causes. Finally, the addition of a proximal anti-rotation screw in the Affixus nail did not seem to confer any benefit.ConclusionWe reported a 22.3% re-operation rate in our cohort of subtrochanteric fractures treated with a long IM nail. We have identified six risk factors associated with re-operation: age < 75 years old, pre-injury femoral neck shaft angle, choice of nail, varus reduction angle, fracture-related infection and non-union. The addition of a proximal anti-rotation screw in the Affixus nail did not confer any benefit.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call