Abstract

The hygroscopicity and phase state of atmospheric aerosols, depending on relative humidity (RH), dominate their impacts on global climate and heterogeneous atmospheric chemistry. It is challenging to achieve full course measurements on hygroscopic mass growth factors (MGFs), deliquescence relative humidity (DRH), efflorescence relative humidity (ERH) and efflorescence kinetics of aerosols at different ambient RH, which concerns the gas, liquid and solid phases. The combination of a rapid scan vacuum FTIR and a RH pulsed controlling system allowed us to directly and synchronously determine ambient RH and MGFs of aerosols, as well as nucleation rates in the efflorescence process with a subsecond time resolution. With an excellent signal-to-noise ratio and high time resolution spectra, the vacuum FTIR method allowed for real-time in situ measurements of water partitioning between gas and particle phases as it changed with RH, as well as the ratio between the number of crystallized aerosol droplets and the total number of particles during the efflorescence of aerosols. The hygroscopicity and efflorescence kinetics of NaCl and (NH4)2SO4 aerosols were studied in linear RH change mode and in pulsed RH change mode. The measured MGF values, DRH and ERH agreed well with theoretical data from the Extended Aerosol Inorganic Model (EAIM) and literature for both the linear and pulsed RH change modes. In addition, the pulsed RH mode also provided both heterogeneous and homogeneous nucleation rates for NaCl and (NH4)2SO4 aerosols. There were significant advantages of the vacuum FTIR method combined with the pulsed RH controlling technique. First, the RH was continuously changed and was determined in real-time with a time resolution of 0.12 s in the pulsed mode. During the RH change process, the water content in the aerosols was measured synchronously with the same time resolution, allowing for high-efficiency measurements of MGFs, ERH and DRH. The deviations of measured MGFs from the EAIM predictions in the RH range of 75–55% were less than ±3.3%. Second, FTIR spectroscopy was sensitive to phase transitions, which provided quantitative information on the ratio of the number of aerosols transformed from droplets to solid particles at ERH, allowing for the measurement of nucleation kinetics during the efflorescence of aerosols.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call