Abstract

Recent intensive studies by scanning probe microscope (SPM) on the recording and detection of extremely minute bit patterns have assumed increasing importance in the field of magnetic recording, because the sharp magnetic tip of the SPM can be used as a kind of micro-manipulator of magnetic domains. This paper investigates submicron magnetic bit recording and detection, in which the tip of a magnetic force microscope (MFM) is used as both the recording head and the magnetic field detector. In the recording procedure, the MFM tip and an excitation coil concentrate magnetic flux as the tip is brought into contact with the medium. When scanned above the medium, the mechanically modulated tip can easily be used to measure the magnetic force gradient by detecting changes in the tip modulation amplitude. Regions with a diameter of about 400 nm can be magnetized and can be erased by a reverse magneic field. Sharper tips will enable magnetization of even smaller regions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.